[{"data":1,"prerenderedAt":923},["ShallowReactive",2],{"$fW6VGRXuPUX-ZS41ToWSn973WDengtSuVj_u8T6llD3g":3,"localizations-z6f42lg8slhtpv99inch27fg-en":275,"global-seo-setting":280,"header-setting":328,"footer":406,"navigations":528,"certificates":776,"localizations-pages-z6f42lg8slhtpv99inch27fg-en":918},{"data":4,"meta":274},{"id":5,"title":6,"slug":7,"createdAt":8,"updatedAt":9,"publishedAt":10,"documentId":11,"locale":12,"showOnArticlesPage":13,"disablePrerender":13,"prerenderTranslation":13,"category":14,"tagCategory":22,"blogImage":22,"settings":22,"seo":23,"body":27},3402,"Cluster - GUIDE to server room\u002Fdata center monitoring","server-rooms","2026-06-30T10:31:13.811Z","2026-06-30T12:12:43.434Z","2026-06-30T12:13:24.902Z","z6f42lg8slhtpv99inch27fg","en",false,{"id":15,"name":16,"slug":17,"createdAt":18,"updatedAt":19,"publishedAt":20,"documentId":21,"locale":12},3,"Temperature monitoring","temperature-monitoring","2023-12-12T13:20:36.357Z","2024-01-22T08:55:47.862Z","2023-12-12T13:21:18.614Z","asuh8dzzhqmz4rigs19wy0aa",null,{"id":24,"pageTitle":25,"shortDescription":26,"noIndex":13,"noAI":13,"noFollow":13,"Schema":22,"canonicalURL":22,"ogTitle":22,"ogDescription":22,"noSitemap":13,"schemaType":22,"image":22},4480,"Server room temperature monitoring: ranges, sensors, alerts | Eupry","What temperature and humidity should a server room be? ASHRAE ranges, sensor placement, and alert thresholds for monitoring server rooms and data centers.\n",[28,73,111,118,123,153,158,163,194,199,204,229,233,270],{"__component":29,"id":30,"title":31,"content":32,"blockId":22,"ulStyle":22,"video":22,"auto play":13,"imageLeftTextRight":13,"preTitle":33,"preTitleColor":34,"ctaInfoText":35,"titleLevel":36,"imageUrl":22,"subTitle":22,"verticalCenteredText":37,"hideOnMobile":13,"hideTopDecoration":13,"hideLastUpdated":13,"buttons":38,"media":46,"employee":22},"blocks.media-and-text-split-view",17313,"Server room and data center temperature monitoring","Server rooms fail quietly. A cooling unit drifts, a return-air vent gets blocked, humidity creeps up over a long weekend, and the first sign of trouble is a thermal shutdown or a shortened hardware lifespan. Continuous temperature and humidity monitoring is how you see the problem while it is still cheap to fix.\n\nThis guide covers what conditions to hold, why they matter, how to monitor them, and where to put your sensors.","A practical guide:","Brain Freeze Dark","A one-page checklist for ranges, sensor placement, and alert thresholds.","h1",true,[39],{"id":40,"title":41,"href":42,"type":43,"size":44,"arrow":45,"blockId":22,"fullWidth":13,"quizId":22,"icon":22,"lucideIcon":22},16317,"Download a server room monitoring checklist","#form","brain-freeze","default","down",{"id":47,"name":48,"alternativeText":49,"caption":22,"width":50,"height":51,"formats":52,"hash":65,"ext":54,"mime":57,"size":66,"url":67,"previewUrl":22,"provider":68,"provider_metadata":69,"createdAt":70,"updatedAt":71,"documentId":72,"publishedAt":70,"focalPoint":22},1961,"Checklist.jpg","Isometric illustration of a clipboard checklist with four teal checkmarks on a light blue gradient background",1879,1144,{"thumbnail":53},{"ext":54,"url":55,"hash":56,"mime":57,"name":58,"path":22,"size":59,"width":60,"height":61,"sizeInBytes":62,"provider_metadata":63},".jpg","https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1774009650\u002Fthumbnail_Checklist_5e67060c61.jpg","thumbnail_Checklist_5e67060c61","image\u002Fjpeg","thumbnail_Checklist.jpg",2.36,245,149,2363,{"public_id":56,"resource_type":64},"image","Checklist_5e67060c61",211.47,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1774009650\u002FChecklist_5e67060c61.jpg","cloudinary",{"public_id":65,"resource_type":64},"2026-03-20T12:27:31.463Z","2026-03-26T11:34:30.298Z","q5a9kgewyevl9azcnkpmy3oc",{"__component":74,"id":75,"title":76,"description":22,"blockId":22,"imageUrl":22,"layout":77,"hideOnMobile":13,"items":78,"media":22},"blocks.table-of-contents",271,"Table of contents","fullWidth",[79,83,87,91,95,99,103,107],{"id":80,"label":81,"link":82},1719,"What temperature should a server room be?","#what",{"id":84,"label":85,"link":86},1720,"What humidity should a server room be?","#humidity",{"id":88,"label":89,"link":90},1721,"Why is temperature monitoring relevant for server rooms and data centers?","#why",{"id":92,"label":93,"link":94},1722,"How much headroom do you have for server room temperature monitoring?","#much",{"id":96,"label":97,"link":98},1723,"Where to place temperature and humidity sensors","#place",{"id":100,"label":101,"link":102},1724,"How to set alert thresholds for data center and server room environmental monitoring?","#alert",{"id":104,"label":105,"link":106},1725,"How do you choose a monitoring approach for data centers and server rooms?","#approach",{"id":108,"label":109,"link":110},1726,"FAQ about server room and data center environmental monitoring","#FAQ",{"__component":112,"id":113,"text":114,"columns":115,"title":22,"blockId":116,"hideOnMobile":13,"ulStyle":22,"ulColor":22,"buttons":117},"blocks.text",4535,"## What temperature should a server room be?\n\nFor most IT equipment, ASHRAE recommends an inlet air temperature of 18 °C to 27 °C (64 °F to 81 °F). This is the range ASHRAE's TC 9.9 committee defines for long-term reliability across its main equipment classes.\n\nThat said, the figure that matters is the temperature of the air entering the equipment, not the temperature in the middle of the room. Servers draw cool air in the front and exhaust hot air out the back, so a reading taken at the wrong spot can look fine while an inlet a meter away is running hot.\n\nManufacturer specifications can be tighter than the ASHRAE range, so when a vendor states a narrower window for a specific unit, that takes precedence.","one","what",[],{"__component":112,"id":119,"text":120,"columns":115,"title":22,"blockId":121,"hideOnMobile":13,"ulStyle":22,"ulColor":22,"buttons":122},4536,"## What humidity should a server room be?\n\nHumidity matters as much as temperature, for opposite reasons at each extreme. Air that is too dry raises the risk of electrostatic discharge; air that is too humid raises the risk of condensation and corrosion on components.\n\nASHRAE commonly cites an acceptable relative humidity range of 20% to 80%, with many operators holding a tighter 40% to 60% to stay clear of both failure modes. Because relative humidity shifts as air temperature changes, some facilities track dew point alongside it for a more stable picture of moisture.\n\n","humidity",[],{"__component":29,"id":124,"title":89,"content":125,"blockId":126,"ulStyle":22,"video":22,"auto play":13,"imageLeftTextRight":13,"preTitle":22,"preTitleColor":22,"ctaInfoText":22,"titleLevel":127,"imageUrl":22,"subTitle":22,"verticalCenteredText":13,"hideOnMobile":13,"hideTopDecoration":13,"hideLastUpdated":13,"buttons":128,"media":129,"employee":22},17311,"A wall thermostat tells you the temperature at one point, right now. It does not tell you what happened at 3 a.m., it does not warn the on-call engineer, and it does not show you the gradient between a cool aisle and a hot rack.\n\nContinuous monitoring closes those gaps. It records conditions at intervals so you have a history to investigate, it covers multiple points so you catch hot spots a single reading would miss, and it raises an alert the moment a reading drifts out of range, while there is still time to act.\n\nThe cost of getting this wrong is rarely the sensor. It is the unplanned downtime, the equipment replaced early because it ran hot for months, or the service-level commitment missed because no one saw the drift coming.","why","h2",[],{"id":130,"name":131,"alternativeText":132,"caption":22,"width":133,"height":134,"formats":135,"hash":145,"ext":54,"mime":57,"size":146,"url":147,"previewUrl":22,"provider":68,"provider_metadata":148,"createdAt":149,"updatedAt":150,"documentId":151,"publishedAt":152,"focalPoint":22},1205,"Question mark.jpg","3D isometric white question mark icon with dark shadow on a light blue gradient background",1200,903,{"thumbnail":136},{"ext":54,"url":137,"hash":138,"mime":57,"name":139,"path":22,"size":140,"width":141,"height":142,"sizeInBytes":143,"provider_metadata":144},"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1753967295\u002Fthumbnail_Question_mark_2e23841707.jpg","thumbnail_Question_mark_2e23841707","thumbnail_Question mark.jpg",3.68,208,156,3680,{"public_id":138,"resource_type":64},"Question_mark_2e23841707",192.21,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1753967295\u002FQuestion_mark_2e23841707.jpg",{"public_id":145,"resource_type":64},"2025-07-31T13:08:16.824Z","2026-03-26T11:07:38.872Z","mvq12t6g879c2yj2uuer89h8","2025-07-31T13:08:16.826Z",{"__component":112,"id":154,"text":155,"columns":115,"title":22,"blockId":156,"hideOnMobile":13,"ulStyle":22,"ulColor":22,"buttons":157},4537,"## Recommended vs. allowable: How much headroom do you have for server room temperature monitoring?\n\nASHRAE publishes two envelopes, and the difference is worth understanding.\n\n- **Recommended:** The 18 °C to 27 °C (64 °F to 81 °F) range designed for long-term reliability and energy efficiency. This is where you should aim to operate.\n- **Allowable:** A wider range, varying by equipment class, where hardware will still function but may experience more wear or higher energy use over time. Class A1 enterprise equipment, for example, has an allowable range of roughly 15 °C to 32 °C (59 °F to 90 °F).\n\nTreat the allowable range as short-term tolerance for an event like a cooling failure, not as a target. Running continuously at the top of allowable trades hardware life and efficiency for a slightly lower cooling bill.\n\n","much",[],{"__component":112,"id":159,"text":160,"columns":115,"title":97,"blockId":161,"hideOnMobile":13,"ulStyle":22,"ulColor":22,"buttons":162},4538,"A single sensor on the wall is the most common monitoring mistake. Conditions vary significantly between the floor and the ceiling, between the cold aisle and the hot aisle, and between an empty rack and a fully loaded one.\n\nFor meaningful coverage, ASHRAE TC 9.9 points toward monitoring server inlets at the bottom, middle, and top of the rack, since the top of a rack often runs warmest. From there, a workable approach is:\n\n- **Per rack or rack row:** Place sensors at inlet height, with extra attention to the top of the rack.\n- **Cold aisle and hot aisle:** Monitor both, so you can see the actual temperature rise across the equipment.\n- **Known risk points:** Add coverage near cooling unit returns, doorways, and any high-density rack.\n\nThe goal is enough points to characterize the room honestly, not a sensor on every shelf.\n\n**Also read**: [Where to place data loggers during temperature mapping](\u002Ftemperature-mapping\u002Fdata-logger-placement\u002F)\n\n","place",[],{"__component":164,"id":165,"title":166,"lead":167,"hubspotFormId":168,"blockId":169,"hubspotMeetingUrl":22,"titleLevel":127,"preTitle":170,"preTitleColor":34,"imageUrl":22,"hideOnMobile":13,"media":171},"blocks.download-form",3919,"Server room environmental monitoring checklist","Download a step-by-step checklist covering temperature and humidity, sensor placement, and alert thresholds for server rooms and data centers.","67400a68-104e-43ae-b96f-394782dae502","form","Download",{"id":172,"name":173,"alternativeText":22,"caption":22,"width":174,"height":175,"formats":176,"hash":187,"ext":178,"mime":181,"size":188,"url":189,"previewUrl":22,"provider":68,"provider_metadata":190,"createdAt":191,"updatedAt":191,"documentId":192,"publishedAt":193,"focalPoint":22},2161,"server room temperature monitoring.png",886,690,{"thumbnail":177},{"ext":178,"url":179,"hash":180,"mime":181,"name":182,"path":22,"size":183,"width":184,"height":142,"sizeInBytes":185,"provider_metadata":186},".png","https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1782821461\u002Fthumbnail_server_room_temperature_monitoring_b742392e0f.png","thumbnail_server_room_temperature_monitoring_b742392e0f","image\u002Fpng","thumbnail_server room temperature monitoring.png",35.89,200,35891,{"public_id":180,"resource_type":64},"server_room_temperature_monitoring_b742392e0f",450.65,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1782821462\u002Fserver_room_temperature_monitoring_b742392e0f.png",{"public_id":187,"resource_type":64},"2026-06-30T12:11:02.993Z","cmbrqfx02iux7nfr8suiy2y3","2026-06-30T12:11:02.994Z",{"__component":29,"id":195,"title":101,"content":196,"blockId":197,"ulStyle":22,"video":22,"auto play":13,"imageLeftTextRight":13,"preTitle":22,"preTitleColor":22,"ctaInfoText":22,"titleLevel":127,"imageUrl":22,"subTitle":22,"verticalCenteredText":13,"hideOnMobile":13,"hideTopDecoration":13,"hideLastUpdated":13,"buttons":198,"media":22,"employee":22},17312,"An alert is only useful if it arrives in time and reaches someone who can act. A few principles:\n\n- **Set thresholds inside the safe range, not at its edge.** A warning at 26 °C gives you time; an alert at 32 °C tells you the damage may already be underway.\n- **Use a warning level and a critical level.** A first nudge lets you investigate calmly; a second, louder alarm signals an emergency.\n- **Route alerts to a person, with escalation.** If the first contact does not acknowledge, the alert should move to a backup, day or night.","alert",[],{"__component":112,"id":200,"text":201,"columns":115,"title":105,"blockId":202,"hideOnMobile":13,"ulStyle":22,"ulColor":22,"buttons":203},4539,"Environmental monitoring options range from a basic standalone sensor with a local display to a wireless system that logs continuously and sends remote alerts. For a server room you cannot afford to lose, the features that matter are continuous logging with a history you can review, remote alerts that reach you off-site, local data backup so a network outage does not create a gap, and sensors that stay accurate over time through calibration.\n\nEupry's [wireless data loggers](\u002Fsolutions\u002Fwireless-data-loggers\u002F) cover temperature and humidity across a room, store readings locally as a backup, and send instant alerts when conditions drift, which fits the way server rooms actually fail.\n\n**Also read**: [Server room temperature and humidity monitoring](\u002Fsolutions\u002Fserver-room-temperature-monitoring\u002F)","approach",[],{"__component":205,"id":206,"title":207,"content":22,"blockId":22,"preTitle":22,"preTitleColor":22,"includeInGoogleSchema":37,"hideOnMobile":13,"subTitle":22,"fullWidth":13,"questions":208},"blocks.faq",2759,"Frequently asked questions about server room temperature monitoring",[209,213,217,221,225],{"id":210,"question":211,"answer":212},19052,"What is the ideal server room temperature?","ASHRAE recommends 18 °C to 27 °C (64 °F to 81 °F) for most IT equipment. Manufacturer specs may be tighter.",{"id":214,"question":215,"answer":216},19053,"What humidity level should a server room have?","ASHRAE cites 20% to 80% relative humidity as acceptable, with 40% to 60% often preferred to limit static and condensation.",{"id":218,"question":219,"answer":220},19054,"How many temperature sensors does a server room need?","Enough to cover each rack row and both aisles, with extra points at the top of racks and near cooling returns.",{"id":222,"question":223,"answer":224},19055,"What happens if a server room gets too hot?","Equipment throttles or shuts down to protect itself, and sustained heat shortens hardware lifespan.",{"id":226,"question":227,"answer":228},19056,"Is one wall-mounted sensor enough?","Rarely. Conditions vary between floor and ceiling and between aisles, so a single point misses hot spots.",{"__component":112,"id":230,"text":231,"columns":115,"title":22,"blockId":22,"hideOnMobile":13,"ulStyle":22,"ulColor":22,"buttons":232},4540,"## Related reading\n\n- [Server room temperature and humidity monitoring](\u002Fsolutions\u002Fserver-room-temperature-monitoring\u002F)\n- [Wireless data loggers](\u002Fsolutions\u002Fwireless-data-loggers\u002F)\n- [Where to place data loggers during temperature mapping](\u002Ftemperature-mapping\u002Fdata-logger-placement\u002F)",[],{"__component":29,"id":234,"title":235,"content":236,"blockId":22,"ulStyle":22,"video":22,"auto play":13,"imageLeftTextRight":37,"preTitle":22,"preTitleColor":22,"ctaInfoText":22,"titleLevel":127,"imageUrl":22,"subTitle":22,"verticalCenteredText":37,"hideOnMobile":13,"hideTopDecoration":13,"hideLastUpdated":13,"buttons":237,"media":249,"employee":22},17314,"Monitor your server room with confidence","Eupry provides wireless temperature and humidity monitoring with real-time alerts, local data backup, and accredited calibration included. See how it works, or download the catalog for specifications and options.",[238,243],{"id":239,"title":240,"href":241,"type":242,"size":44,"arrow":45,"blockId":22,"fullWidth":13,"quizId":22,"icon":22,"lucideIcon":22},16318,"Download a catalog","\u002Fserver-room-temperature-monitoring\u002F#catalog","hot-pink",{"id":244,"title":245,"href":246,"type":247,"size":44,"arrow":248,"blockId":22,"fullWidth":13,"quizId":22,"icon":22,"lucideIcon":22},16319,"See how it works","\u002Fserver-room-temperature-monitoring\u002F","black","right",{"id":250,"name":251,"alternativeText":252,"caption":22,"width":92,"height":253,"formats":254,"hash":263,"ext":178,"mime":181,"size":264,"url":265,"previewUrl":22,"provider":68,"provider_metadata":266,"createdAt":267,"updatedAt":268,"documentId":269,"publishedAt":267,"focalPoint":22},2160,"Server room temperature monitoring02.png","Eupry sensors and dashboard monitoring temperature in a pharmaceutical data center with server racks",1476,{"thumbnail":255},{"ext":178,"url":256,"hash":257,"mime":181,"name":258,"path":22,"size":259,"width":260,"height":142,"sizeInBytes":261,"provider_metadata":262},"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1782734236\u002Fthumbnail_Server_room_temperature_monitoring02_90e9468391.png","thumbnail_Server_room_temperature_monitoring02_90e9468391","thumbnail_Server room temperature monitoring02.png",57.88,182,57884,{"public_id":257,"resource_type":64},"Server_room_temperature_monitoring02_90e9468391",3428.62,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1782734236\u002FServer_room_temperature_monitoring02_90e9468391.png",{"public_id":263,"resource_type":64},"2026-06-29T11:57:17.824Z","2026-06-29T22:01:55.492Z","zk42lkqj9c0fsxrigkxxzsw8",{"__component":271,"id":272,"divider":37,"blockId":22,"hideOnMobile":13,"spacing":273},"blocks.divider",20716,"medium",{},{"data":276,"meta":279},{"id":5,"documentId":11,"slug":7,"locale":12,"localizations":277,"category":278},[],{"id":15,"documentId":21,"slug":17},{},{"data":281,"meta":327},{"id":282,"globalSchema":283,"createdAt":302,"updatedAt":303,"documentId":304,"publishedAt":305,"ogImage":306},1,{"@graph":284,"@context":301},[285,294],{"@id":286,"url":287,"name":288,"@type":289,"publisher":290,"inLanguage":292,"description":293},"https:\u002F\u002Feupry.com\u002F#website","https:\u002F\u002Feupry.com\u002F","Eupry","WebSite",{"@id":291},"https:\u002F\u002Feupry.com\u002F#organization","en-GB","Temperature compliance as a service",{"@id":291,"url":287,"logo":295,"name":296,"@type":297,"sameAs":298},"https:\u002F\u002Feupry.com\u002Flogo.svg","Eupry ApS","Organization",[299,300],"https:\u002F\u002Fwww.facebook.com\u002FEupry\u002F","https:\u002F\u002Fwww.linkedin.com\u002Fcompany\u002F4840125\u002F","https:\u002F\u002Fschema.org","2023-12-09T16:03:40.081Z","2025-11-13T12:01:30.781Z","ds7dln39quasjv0ma3hbdbfl","2025-11-13T12:01:30.729Z",{"id":307,"name":308,"alternativeText":309,"caption":22,"width":133,"height":310,"formats":311,"hash":319,"ext":54,"mime":57,"size":320,"url":321,"previewUrl":22,"provider":68,"provider_metadata":322,"createdAt":323,"updatedAt":324,"documentId":325,"publishedAt":326,"focalPoint":22},665,"GlobalSeo.jpg","Eupry company logo featuring a dark navy arch symbol beside the wordmark \"eupry\" on a soft green and blue gradient background.",630,{"thumbnail":312},{"ext":54,"url":313,"hash":314,"mime":57,"name":315,"path":22,"size":316,"width":60,"height":317,"provider_metadata":318},"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1707215982\u002Fthumbnail_Global_Seo_8122f21b00.jpg","thumbnail_Global_Seo_8122f21b00","thumbnail_GlobalSeo.jpg",2.72,129,{"public_id":314,"resource_type":64},"Global_Seo_8122f21b00",113.96,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1707215982\u002FGlobal_Seo_8122f21b00.jpg",{"public_id":319,"resource_type":64},"2024-02-06T10:39:43.206Z","2026-03-26T10:57:42.317Z","v192fn1eqcrhxwpnhdeiaaok","2025-01-29T12:38:47.261Z",{},{"data":329,"meta":405},{"id":282,"createdAt":330,"updatedAt":331,"documentId":332,"locale":12,"publishedAt":333,"logo":334,"button":349,"menu":361},"2023-11-28T14:01:33.644Z","2026-01-28T15:52:11.416Z","ski8ci2caqfpvlg34xlwvnpn","2026-01-28T15:52:11.097Z",{"id":335,"name":336,"alternativeText":288,"caption":22,"width":337,"height":338,"formats":339,"hash":340,"ext":341,"mime":342,"size":343,"url":344,"previewUrl":22,"provider":345,"provider_metadata":22,"createdAt":346,"updatedAt":347,"documentId":348,"publishedAt":326,"focalPoint":22},11,"Eupry.svg",1502,373,{},"Eupry_f5a9faf2e4",".svg","image\u002Fsvg+xml",3.16,"https:\u002F\u002Fuseful-spirit-ce54045004.media.strapiapp.com\u002FEupry_f5a9faf2e4.svg","strapi-provider-upload-strapi-cloud","2023-11-28T14:01:14.931Z","2024-01-09T10:14:44.698Z","yevykc70mow53iyilka4utgz",{"id":282,"title":350,"blockId":22,"type":247,"size":351,"links":352},"Login","login",[353,357],{"id":354,"title":355,"icon":355,"topBorder":22,"link":356,"blockId":22,"lucideIcon":22},309,"Monitoring","https:\u002F\u002Fapp.eupry.com\u002Fmonitoring\u002F",{"id":358,"title":359,"icon":359,"topBorder":22,"link":360,"blockId":22,"lucideIcon":22},310,"Mapping","https:\u002F\u002Fapp.eupry.com\u002Fapp2\u002F#\u002Feasymap",{"id":362,"title":363,"menuItem":364},5,"About",[365,370,375,380,385,390,395,400],{"id":366,"title":367,"icon":368,"topBorder":22,"link":369,"blockId":22,"lucideIcon":22},27,"About Eupry","Book","\u002Fabout-us",{"id":371,"title":372,"icon":373,"topBorder":22,"link":374,"blockId":22,"lucideIcon":22},214,"Certifications","Award","\u002Fcertifications-accreditations\u002F",{"id":376,"title":377,"icon":378,"topBorder":22,"link":379,"blockId":22,"lucideIcon":22},215,"Trust Hub","CheckmarkCircle","\u002Ftrusthub",{"id":381,"title":382,"icon":383,"topBorder":37,"link":384,"blockId":22,"lucideIcon":22},17,"Contact","Phone","\u002Fcontact",{"id":386,"title":387,"icon":388,"topBorder":37,"link":389,"blockId":22,"lucideIcon":22},18,"Book demo","CalendarDefault","\u002Fbook-demo",{"id":391,"title":392,"icon":393,"topBorder":22,"link":394,"blockId":22,"lucideIcon":22},19,"Support","Headset","https:\u002F\u002Fsupport.eupry.com\u002F",{"id":396,"title":397,"icon":398,"topBorder":37,"link":399,"blockId":22,"lucideIcon":22},28,"Careers","Smiley","\u002Fcareers",{"id":401,"title":402,"icon":403,"topBorder":22,"link":404,"blockId":22,"lucideIcon":22},29,"Partners","MultipleUser","\u002Fpartners",{},{"data":407,"meta":527},{"id":282,"copyright":408,"certifications":37,"createdAt":409,"updatedAt":410,"documentId":411,"locale":12,"publishedAt":412,"links":413,"footer":422},"2026 Eupry ApS, Copenhagen, Denmark. ® All Rights Reserved","2023-11-21T10:35:28.269Z","2026-05-06T12:16:06.560Z","a2qkow7m5zbda8h7om7efkq6","2026-05-06T12:16:05.960Z",[414,418],{"id":415,"title":416,"href":417,"blockId":22,"type":22},6,"Privacy policy","\u002Fprivacy",{"id":419,"title":420,"href":421,"blockId":22,"type":22},8,"Terms and conditions","\u002Fterms-and-conditions",{"id":282,"hideOnMobile":22,"logo":423,"Solution":434,"company":455,"contactPhone":472,"contactEmail":490,"contactLink":493,"use":500,"compare":519},{"id":424,"name":425,"alternativeText":426,"caption":22,"width":427,"height":427,"formats":22,"hash":428,"ext":341,"mime":342,"size":429,"url":430,"previewUrl":22,"provider":345,"provider_metadata":22,"createdAt":431,"updatedAt":432,"documentId":433,"publishedAt":326,"focalPoint":22},2,"Squid.svg","Eupry logo",32,"Union_d2b5856d87",0.58,"https:\u002F\u002Fuseful-spirit-ce54045004.media.strapiapp.com\u002FUnion_d2b5856d87.svg","2023-11-21T10:33:23.460Z","2024-01-25T11:11:51.664Z","ni50bf3tpxpd9bn164ib849m",[435,439,442,444,448,451],{"id":436,"title":437,"href":438,"blockId":22,"type":22},14,"Data loggers","\u002Fdata-logger",{"id":440,"title":355,"href":441,"blockId":22,"type":22},15,"\u002Ftemperature-monitoring",{"id":282,"title":359,"href":443,"blockId":22,"type":22},"\u002Ftemperature-mapping",{"id":445,"title":446,"href":447,"blockId":22,"type":22},16,"Calibration","\u002Ftemperature-calibration\u002F",{"id":449,"title":450,"href":374,"blockId":22,"type":22},127,"Certifications & accreditations",{"id":452,"title":453,"href":454,"blockId":22,"type":22},436,"Service level agreements","\u002Fservice-level-agreements\u002F",[456,458,459,462,464,468],{"id":391,"title":363,"href":457,"blockId":22,"type":22},"\u002Fabout-us\u002F",{"id":424,"title":392,"href":394,"blockId":22,"type":22},{"id":460,"title":397,"href":461,"blockId":22,"type":22},20,"\u002Fcareers\u002F",{"id":463,"title":402,"href":404,"blockId":22,"type":22},107,{"id":465,"title":466,"href":467,"blockId":22,"type":22},22,"LinkedIn","https:\u002F\u002Fwww.linkedin.com\u002Fcompany\u002Feupry\u002F",{"id":469,"title":470,"href":471,"blockId":22,"type":22},853,"AI info","\u002Fabout-us\u002Fai-info",[473,478,483,487],{"id":282,"phoneNumberLink":474,"phoneNumberTitle":474,"addressLine1":475,"addressLine2":476,"flag":477},"+45 53 51 77 00","Hejrevej 28","2400 Copenhagen, Denmark","🇩🇰",{"id":15,"phoneNumberLink":479,"phoneNumberTitle":479,"addressLine1":480,"addressLine2":481,"flag":482},"+1 (857) 214-5305","421 N. Harrington Street., Suite. 340 ","Raleigh NC 27603, USA","🇺🇸",{"id":484,"phoneNumberLink":485,"phoneNumberTitle":485,"addressLine1":22,"addressLine2":22,"flag":486},4,"+44 2045 713534","🇬🇧",{"id":415,"phoneNumberLink":488,"phoneNumberTitle":488,"addressLine1":22,"addressLine2":22,"flag":489},"+353 1 9026530","🇮🇪",[491],{"id":282,"email":492},"contact@eupry.com",[494,497],{"id":15,"title":495,"href":496,"blockId":22,"type":22},"Book a demo","\u002Fbook-demo\u002F",{"id":498,"title":499,"href":384,"blockId":22,"type":22},433,"Get in touch",[501,504,508,512,515],{"id":484,"title":502,"href":503,"blockId":22,"type":22},"Use cases","\u002Fuse-case",{"id":505,"title":506,"href":507,"blockId":22,"type":22},24,"Pharma","\u002Findustries\u002Fpharma",{"id":509,"title":510,"href":511,"blockId":22,"type":44},25,"Biotech","\u002Findustries\u002Fbiotech",{"id":396,"title":513,"href":514,"blockId":22,"type":22},"Healthcare logistics","\u002Findustries\u002Flogistics\u002F",{"id":516,"title":517,"href":518,"blockId":22,"type":44},2058,"Hospitals","\u002Fsolutions\u002Fhospital-temperature-monitoring\u002F",[520,523],{"id":362,"title":521,"href":522,"blockId":22,"type":22},"USB data loggers vs. Eupry","\u002Fdata-logger\u002Fusb-data-logger",{"id":524,"title":525,"href":526,"blockId":22,"type":22},438,"Traditional vs. continuous mapping","\u002Ftemperature-mapping\u002Fcontinuous-mapping-infographic\u002F",{},{"data":529,"meta":774},[530,608,616,651,755],{"id":531,"title":532,"createdAt":533,"updatedAt":534,"publishedAt":535,"link":22,"order":282,"documentId":536,"locale":12,"submenu":537},64,"Solution","2026-04-30T12:50:24.735Z","2026-05-06T09:28:57.998Z","2026-05-06T09:28:58.128Z","vldgdcsx7kr5yrgvxl3twjk4",[538],{"__component":539,"id":335,"columns":540},"navigation.mega-menu",[541,566,591],{"id":542,"label":543,"blocks":544},31,"Column 1",[545],{"__component":546,"id":542,"title":547,"items":548},"blocks.mega-menu-list","Our solutions",[549,556,561],{"id":550,"title":551,"description":552,"link":553,"tag":554,"tagColor":555},126,"One-stop thermal compliance","Validation, monitoring, and calibration in one GxP-ready solution. One vendor, all you need.","\u002Fsolutions\u002Ftemperature-compliance","CORE","cyan",{"id":449,"title":557,"description":558,"link":559,"tag":22,"tagColor":560},"Real-time monitoring","Automated, wireless monitoring for GxP. Real-time alerts and audit reports in 3 clicks.","\u002Fsolutions\u002Fmonitoring","grey",{"id":562,"title":563,"description":564,"link":565,"tag":22,"tagColor":560},128,"Automated calibration","ISO 17025-accredited calibration, done on site, in minutes. Cut calibration time by up to 95%.","\u002Fsolutions\u002Fcalibration",{"id":427,"label":567,"blocks":568},"Column 2",[569],{"__component":546,"id":427,"title":570,"items":571},"CQV services",[572,576,581,586],{"id":317,"title":573,"description":574,"link":575,"tag":22,"tagColor":560},"IQ, OQ, PQ services","IQ, OQ, and PQ services for GMP and GDP. One provider for your full validation process.","\u002Fsolutions\u002Fiq-oq-pq-services\u002F",{"id":577,"title":578,"description":579,"link":580,"tag":22,"tagColor":560},130,"Temperature mapping","GxP-compliant mapping services and equipment. Avoid delays, errors, and compliance risks.","\u002Fsolutions\u002Fmapping",{"id":582,"title":583,"description":584,"link":585,"tag":22,"tagColor":560},131,"CONTINUOUS mapping","Continuous mapping and monitoring in one setup. Eliminate re-mappings and gain constant compliance.","\u002Fsolutions\u002Fcontinuous-mapping\u002F",{"id":587,"title":588,"description":589,"link":590,"tag":22,"tagColor":560},132,"Steam sterilization validation","Steam sterilization validation services for GMP. Autoclave and SIP validation, fully covered.","\u002Fsolutions\u002Fsteam-sterilization-validation\u002F",{"id":592,"label":593,"blocks":594},33,"Column 3",[595],{"__component":546,"id":592,"title":596,"items":597},"Hardware",[598,603],{"id":599,"title":600,"description":601,"link":602,"tag":22,"tagColor":560},133,"Wireless data loggers","Wi-Fi data loggers built for GxP. Real-time data, automated transfer, and calibration included.","\u002Fsolutions\u002Fwireless-data-loggers",{"id":604,"title":605,"description":606,"link":607,"tag":22,"tagColor":560},134,"Sensors","Temperature, humidity, and CO2 sensors for any GxP setup. Same hardware for monitoring and mapping.","\u002Fsolutions\u002Fsensors",{"id":609,"title":610,"createdAt":611,"updatedAt":611,"publishedAt":612,"link":613,"order":424,"documentId":614,"locale":12,"submenu":615},35,"Products","2025-12-19T01:29:03.459Z","2025-12-19T08:56:42.416Z","\u002Fproducts\u002F","iozurp0tpkq8tsan1yt9pzdh",[],{"id":617,"title":502,"createdAt":618,"updatedAt":619,"publishedAt":620,"link":22,"order":15,"documentId":621,"locale":12,"submenu":622},48,"2025-01-13T09:34:50.011Z","2026-03-16T08:38:18.805Z","2026-03-16T08:38:19.725Z","qewu04orvxevg5vn13wkq6fq",[623],{"__component":624,"id":625,"title":22,"menuItem":626},"navigation.submenu",40,[627,631,633,637,640,643,646],{"id":628,"title":629,"icon":368,"topBorder":22,"link":630,"blockId":22,"lucideIcon":22},362,"Case studies","\u002Fcases",{"id":632,"title":502,"icon":378,"topBorder":22,"link":503,"blockId":22,"lucideIcon":22},363,{"id":634,"title":635,"icon":636,"topBorder":37,"link":22,"blockId":22,"lucideIcon":22},364,"Industries","none",{"id":638,"title":506,"icon":506,"topBorder":22,"link":639,"blockId":22,"lucideIcon":22},365,"\u002Findustries\u002Fpharma\u002F",{"id":641,"title":642,"icon":642,"topBorder":22,"link":514,"blockId":22,"lucideIcon":22},366,"Logistics",{"id":644,"title":510,"icon":510,"topBorder":22,"link":645,"blockId":22,"lucideIcon":22},367,"\u002Findustries\u002Fbiotech\u002F",{"id":647,"title":648,"icon":649,"topBorder":22,"link":650,"blockId":22,"lucideIcon":22},368,"Laboratories","Laboratory","\u002Findustries\u002Flaboratories\u002F",{"id":652,"title":653,"createdAt":654,"updatedAt":655,"publishedAt":656,"link":22,"order":484,"documentId":657,"locale":12,"submenu":658},75,"Knowledge","2026-04-30T12:54:42.955Z","2026-05-29T12:13:39.059Z","2026-05-29T12:13:40.854Z","whg5ji10iuvn13a2alpippex",[659],{"__component":539,"id":445,"columns":660},[661,690,726],{"id":662,"label":543,"blocks":663},46,[664],{"__component":546,"id":662,"title":665,"items":666},"Guidelines for",[667,672,676,681,686],{"id":668,"title":669,"description":670,"link":671,"tag":22,"tagColor":560},185,"Monitoring systems","Best practices and key features for choosing a temperature monitoring system in GxP.","\u002Ftemperature-monitoring\u002F",{"id":673,"title":578,"description":674,"link":675,"tag":22,"tagColor":560},186,"Tips, frameworks, and common pitfalls of temperature mapping in GxP.","\u002Ftemperature-mapping\u002F",{"id":677,"title":678,"description":679,"link":680,"tag":22,"tagColor":560},187,"Continuous mapping","The framework, key benefits, and steps to make continuous mapping part of your operations.","\u002Ftemperature-mapping\u002Fcontinuous-temperature-mapping",{"id":682,"title":683,"description":684,"link":685,"tag":22,"tagColor":560},188,"Choosing data loggers","What to look for when choosing data loggers for GxP – features, types, and comparisons.","\u002Fdata-logger\u002F",{"id":687,"title":688,"description":689,"link":447,"tag":22,"tagColor":560},189,"Temperature calibration","Calibration methods, standards, and procedures in GxP. From accredited vs. traceable to common pitfalls.",{"id":691,"label":567,"blocks":692},47,[693],{"__component":546,"id":691,"title":694,"items":695},"Regulations",[696,701,706,711,716,721],{"id":697,"title":698,"description":699,"link":700,"tag":22,"tagColor":560},190,"Key guidelines","An overview of the key regulations, standards, and guidelines for temperature compliance.","\u002Fregulations-temperature-compliance\u002F",{"id":702,"title":703,"description":704,"link":705,"tag":22,"tagColor":560},191,"ISO 17025","The international standard for calibration laboratories. What accreditation means and when you need it.","\u002Fregulations-temperature-compliance\u002Fiso-17025\u002F",{"id":707,"title":708,"description":709,"link":710,"tag":22,"tagColor":560},192,"FDA 21 CFR Part 11","What FDA 21 CFR Part 11 requires for digital records and electronic signatures in GxP.","\u002Fregulations-temperature-compliance\u002F21-cfr-part-11\u002F",{"id":712,"title":713,"description":714,"link":715,"tag":22,"tagColor":560},193,"GxP guidelines","How GxP applies to temperature compliance across monitoring, mapping, and calibration.","\u002Fregulations-temperature-compliance\u002Fgxp\u002F",{"id":717,"title":718,"description":719,"link":720,"tag":22,"tagColor":560},194,"GMP guidelines","Meeting GMP temperature requirements across pharmaceutical manufacturing, storage, and documentation.","\u002Fregulations-temperature-compliance\u002Fgmp",{"id":722,"title":723,"description":724,"link":725,"tag":22,"tagColor":560},195,"GDP guidelines","Meeting GDP requirements across storage, distribution, and the cold chain.","\u002Fgdp",{"id":617,"label":593,"blocks":727},[728],{"__component":546,"id":617,"title":729,"items":730},"Resources",[731,736,741,746,751],{"id":732,"title":733,"description":734,"link":735,"tag":22,"tagColor":560},196,"Webinars","Live and on-demand sessions on mapping, monitoring, validation, and compliance practices.","\u002Fwebinars\u002F",{"id":737,"title":738,"description":739,"link":740,"tag":22,"tagColor":560},197,"Articles","Articles and deep dives on GxP temperature compliance – from mapping to monitoring and beyond.","\u002Farticles\u002F",{"id":742,"title":743,"description":744,"link":745,"tag":22,"tagColor":560},198,"Guides & checklists","Practical checklists, templates, and guides for monitoring, mapping, validation, and calibration.","\u002Fguides",{"id":747,"title":748,"description":749,"link":750,"tag":22,"tagColor":560},199,"Tools","Free, interactive tools for planning mapping studies and validating your sensor setup.","\u002Ftools",{"id":184,"title":752,"description":753,"link":754,"tag":22,"tagColor":560},"GxP glossary","Key GxP and temperature compliance terminology – what each term means in practice.","\u002Fgxp-glossary\u002F",{"id":756,"title":757,"createdAt":758,"updatedAt":759,"publishedAt":760,"link":22,"order":362,"documentId":761,"locale":12,"submenu":762},36,"Pricing","2023-11-28T14:07:54.557Z","2025-12-19T01:28:25.534Z","2025-12-19T08:56:42.723Z","phfzohw4a0mf4pabqcfn3nt5",[763],{"__component":624,"id":396,"title":22,"menuItem":764},[765,768,771],{"id":766,"title":767,"icon":636,"topBorder":22,"link":22,"blockId":22,"lucideIcon":22},216,"Our prices",{"id":769,"title":355,"icon":355,"topBorder":22,"link":770,"blockId":22,"lucideIcon":22},217,"\u002Ftemperature-monitoring\u002Fmonitoring-price",{"id":772,"title":359,"icon":359,"topBorder":22,"link":773,"blockId":22,"lucideIcon":22},218,"\u002Ftemperature-mapping\u002Fmapping-price",{"pagination":775},{"page":282,"pageSize":460,"pageCount":282,"total":362},{"data":777,"meta":916},[778,797,815,833,862,880,898],{"id":396,"createdAt":779,"updatedAt":780,"publishedAt":781,"Name":703,"link":22,"documentId":782,"order":282,"logo":783},"2023-11-14T10:11:31.675Z","2025-12-19T11:06:38.786Z","2025-12-19T11:07:35.751Z","l9gpf08myj07cm4rripyefti",{"id":784,"name":785,"alternativeText":786,"caption":22,"width":787,"height":788,"formats":22,"hash":789,"ext":178,"mime":181,"size":790,"url":791,"previewUrl":22,"provider":68,"provider_metadata":792,"createdAt":793,"updatedAt":794,"documentId":795,"publishedAt":796,"focalPoint":22},1666,"ISO 17025 - Certification.png","ISO 17025 certification logo with globe graphic and ISO text on dark circular emblem",105,109,"ISO_17025_Certification_3690d6870f",7.05,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766048545\u002FISO_17025_Certification_3690d6870f.png",{"public_id":789,"resource_type":64},"2025-12-18T09:02:25.962Z","2026-03-26T11:23:55.138Z","hnqqomlonwvqy4rkqasuj245","2025-12-18T09:02:25.963Z",{"id":401,"createdAt":798,"updatedAt":799,"publishedAt":800,"Name":801,"link":22,"documentId":802,"order":424,"logo":803},"2023-12-21T14:36:50.697Z","2025-12-19T11:06:44.199Z","2025-12-19T11:07:35.791Z","ISO 9001","r5pk1e7fmbeb9ef9xakdhipc",{"id":804,"name":805,"alternativeText":806,"caption":22,"width":787,"height":788,"formats":22,"hash":807,"ext":178,"mime":181,"size":808,"url":809,"previewUrl":22,"provider":68,"provider_metadata":810,"createdAt":811,"updatedAt":812,"documentId":813,"publishedAt":814,"focalPoint":22},1667,"ISO 9001 - Certification.png","ISO 9001 certification logo with globe symbol and ISO text in dark navy blue","ISO_9001_Certification_a5d52db83d",7.01,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766048545\u002FISO_9001_Certification_a5d52db83d.png",{"public_id":807,"resource_type":64},"2025-12-18T09:02:26.279Z","2026-03-26T11:23:55.132Z","zeod9eprqjl93dr8emxdsfd1","2025-12-18T09:02:26.280Z",{"id":816,"createdAt":817,"updatedAt":818,"publishedAt":819,"Name":820,"link":22,"documentId":821,"order":15,"logo":822},30,"2025-08-04T08:47:35.688Z","2025-12-19T11:06:49.406Z","2025-12-19T11:07:35.800Z","ISO 27001","uy1w7kpcvjextm3jrqhs14ur",{"id":823,"name":824,"alternativeText":825,"caption":22,"width":787,"height":788,"formats":22,"hash":826,"ext":178,"mime":181,"size":827,"url":828,"previewUrl":22,"provider":68,"provider_metadata":829,"createdAt":830,"updatedAt":831,"documentId":832,"publishedAt":830,"focalPoint":22},1669,"ISO 27001 - Certification.png","ISO 27001 certification badge with globe icon and ISO organization logo in dark circular emblem","ISO_27001_Certification_ad6992a8c5",7.1,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766048545\u002FISO_27001_Certification_ad6992a8c5.png",{"public_id":826,"resource_type":64},"2025-12-18T09:02:27.174Z","2026-03-26T11:23:55.161Z","twgl9vee2jvtynp9qwyyylxj",{"id":834,"createdAt":835,"updatedAt":836,"publishedAt":837,"Name":838,"link":22,"documentId":839,"order":484,"logo":840},34,"2025-12-19T09:38:40.126Z","2025-12-19T11:06:54.572Z","2025-12-19T11:07:35.823Z","ISO 14001","jnpel2xaq9jq37g307jnesyw",{"id":841,"name":842,"alternativeText":843,"caption":22,"width":174,"height":844,"formats":845,"hash":854,"ext":178,"mime":181,"size":855,"url":856,"previewUrl":22,"provider":68,"provider_metadata":857,"createdAt":858,"updatedAt":859,"documentId":860,"publishedAt":861,"focalPoint":22},1711,"Dark grey - ISO 14001.png","ISO 14001 certification logo with globe graphic in dark grey",911,{"thumbnail":846},{"ext":178,"url":847,"hash":848,"mime":181,"name":849,"path":22,"size":850,"width":851,"height":142,"sizeInBytes":852,"provider_metadata":853},"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766138121\u002Fthumbnail_Dark_grey_ISO_14001_2a35125955.png","thumbnail_Dark_grey_ISO_14001_2a35125955","thumbnail_Dark grey - ISO 14001.png",14.4,152,14396,{"public_id":848,"resource_type":64},"Dark_grey_ISO_14001_2a35125955",60.95,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766138121\u002FDark_grey_ISO_14001_2a35125955.png",{"public_id":854,"resource_type":64},"2025-12-19T09:55:22.113Z","2026-03-26T11:25:35.667Z","ggid27pls4xjli26uz3ccdqx","2025-12-19T09:55:22.114Z",{"id":542,"createdAt":863,"updatedAt":864,"publishedAt":865,"Name":866,"link":22,"documentId":867,"order":362,"logo":868},"2025-12-18T09:02:36.965Z","2025-12-19T11:07:07.278Z","2025-12-19T11:07:35.805Z","ilac MRA","b1d6992qy1lizp9dbap7m0yt",{"id":869,"name":870,"alternativeText":871,"caption":22,"width":463,"height":872,"formats":22,"hash":873,"ext":178,"mime":181,"size":874,"url":875,"previewUrl":22,"provider":68,"provider_metadata":876,"createdAt":877,"updatedAt":878,"documentId":879,"publishedAt":877,"focalPoint":22},1668,"ilac MRA - Certification.png","ILAC-MRA mutual recognition arrangement logo with circular radiating lines design",108,"ilac_MRA_Certification_17e7a87db4",8.81,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766048545\u002Filac_MRA_Certification_17e7a87db4.png",{"public_id":873,"resource_type":64},"2025-12-18T09:02:26.489Z","2026-03-26T11:23:55.145Z","uezi4qabpw3meydjx8lk1bx8",{"id":427,"createdAt":881,"updatedAt":882,"publishedAt":883,"Name":884,"link":22,"documentId":885,"order":415,"logo":886},"2025-12-18T09:03:49.826Z","2025-12-19T11:07:21.200Z","2025-12-19T11:07:35.812Z","CEIV","gye94mkc9ubrbatsct8wvdpn",{"id":887,"name":888,"alternativeText":889,"caption":22,"width":872,"height":872,"formats":22,"hash":890,"ext":178,"mime":181,"size":891,"url":892,"previewUrl":22,"provider":68,"provider_metadata":893,"createdAt":894,"updatedAt":895,"documentId":896,"publishedAt":897,"focalPoint":22},1664,"CEIV - Certification.png","IATA CEIV Pharma certification badge with globe icon and text Excellence in Logistics","CEIV_Certification_c4aae498a2",10.18,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766048545\u002FCEIV_Certification_c4aae498a2.png",{"public_id":890,"resource_type":64},"2025-12-18T09:02:25.694Z","2026-03-26T11:23:17.701Z","v5sanbxs8cako81zqfh33h5e","2025-12-18T09:02:25.695Z",{"id":592,"createdAt":899,"updatedAt":900,"publishedAt":901,"Name":708,"link":22,"documentId":902,"order":903,"logo":904},"2025-12-18T09:04:02.802Z","2025-12-19T11:07:28.048Z","2025-12-19T11:07:35.818Z","c5gup4jmecxhverwtykn67st",7,{"id":905,"name":906,"alternativeText":907,"caption":22,"width":872,"height":872,"formats":908,"hash":909,"ext":178,"mime":181,"size":910,"url":911,"previewUrl":22,"provider":68,"provider_metadata":912,"createdAt":913,"updatedAt":914,"documentId":915,"publishedAt":913,"focalPoint":22},1665,"FDA - certification.png","FDA 21 CFR Part 11 compliance certification badge with official FDA logo and regulatory text",{},"FDA_certification_814d4289e3",4.02,"https:\u002F\u002Fres.cloudinary.com\u002Feupry\u002Fimage\u002Fupload\u002Fv1766049598\u002FFDA_certification_814d4289e3.png",{"public_id":909,"resource_type":64},"2025-12-18T09:02:25.833Z","2026-03-26T11:23:55.156Z","i8cb922n6e6a6tfitbrqmbun",{"pagination":917},{"page":282,"pageSize":460,"pageCount":282,"total":903},{"data":919,"meta":922},{"id":5,"documentId":11,"slug":7,"locale":12,"localizations":920,"category":921},[],{"id":15,"documentId":21,"slug":17},{},1782821848986]