Login
Faster, compliant, audit-ready

Warehouse temperature mapping services for GDP compliance

Engineer-led, GxP-compliant temperature mapping for pharmaceutical logistics warehouses – delivered faster, with less disruption, and backed by specialized digital tools.

  • Fast execution, minimal disruptions: With setup in minutes, automated data transfer, remote options, digital reporting, and the elimination of re-mappings.
  • Full compliance confidence: With specialist support and mapping equipment built for GDP, ensuring every study meets your requirements, every time.
  • Lower total costs: With continuous mapping eliminating costly re-mappings, optimized processes, and rented equipment.

Get an instant overview of all service options, equipment specifications, and more.

Trusted by +500 GxP-regulated companies worldwide

The problem

Traditional warehouse mapping slows you down

(and risks compliance)

  • Manual errors = risks

    Errors, lost data, and costly re-testing. Paper-based processes create risk and waste resources.

  • Operational disruption

    Seasonal mappings, (urgent) re-mapping, and lengthy on-site work disrupts operations.

  • Fragmented processes

    Multiple vendors and disconnected systems create complexity, risks, and extra costs.

  • Complex requirements

    Requirements from GDP, USP <1079.4>, CEIV, etc. can be hard to translate into practice.

The solution

Faster, GDP-tailored warehouse mapping solutions

(in less time, at lower cost, with full confidence)

With the fastest mapping solution you will find.

  • Digital mapping software

    Plan, execute, and document studies in one place. Create centrally approved test plans that local teams can run consistently. Export complete reports in minutes.

  • Minimal disruptions

    Choose on-site services with Eupry specialists or a guided remote option that keeps your operation moving. Loggers deploy quickly; calibration happens are done prior; and data is automatically transferred.

  • GDP confidence

    Built for GDP, GMP, and CEIV. FDA 21 CFR Part 11–ready records, ISO 17025 accredited calibration, ISO 27001 information security, and engineer-led execution give you confidence before any audit.

  • Designed for warehouses

    Standardized SOPs and templates for ambient (15–25 °C), cold (2–8 °C), and other pharmaceutical warehouse zones. Roll the same process across facilities with digital protocols and centralized data.

Legal basis and guidance

The mapping solutions are designed with a legal basis in cGMP, USP <1079>, and EudraLex Volume 4 Part 1 Chapter 3, and based on guidance from WHO guidelines (supplement 8 and 7 and annex 8), DKD-R 5, FD X 15-140 (French standard), and the ISPE Standard “Controlled Temperature Chamber Mapping and Monitoring”.

Compliance and quality assurance

All your compliance boxes? Consider them ticked. Additionally, our specialists continuously update the service to adapt to evolving compliance standards, ensuring you remain fully compliant.

  • GDP- and GMP-aligned methodology
  • USP <1079.4> qualification expectations reflected in protocol and reporting
  • CEIV considerations for logistics hubs (handover, alarm ownership, rapid audits)
  • ISO 17025 accredited calibration included
  • ISO 27001 certified information security
  • FDA 21 CFR Part 11–ready electronic records and audit trails
  • Optional IQ/OQ/PQ services for new or modified warehouses
Equipment

Equipment built for warehouse temperature mapping

Whether you choose on-site warehouse mapping, a guided remote service, or a rentable mapping kit, you get the same GDP-compliant setup designed for warehouses. The result: Fast, accurate, and audit-ready data every time.

  • Wireless data loggers, built for warehouse mapping, sending results automatically over Wi-Fi so you can track your study without manual transfers or errors.
  • ISO 17025 or traceable calibration, every logger arrives fully calibrated to GDP standards, eliminating downtime and ensuring compliance.
  • Warehouse validation software, manage your warehouse mapping digitally, review data in real time, and export GDP- and USP-ready reports instantly from anywhere.
Expertise

Specialized in GDP thermal validation

Warehouse mapping specialists on-site and on call

GDP and GMP compliance is what we do. After thousands of GxP mappings, we understand the evolving standards of pharmaceutical compliance and can turn the complex requirements and operational needs of your healthcare warehouse and any other facilties into audit-ready results.

Mapping service options

Flexible options to fit your warehouse mapping

Pick a solution that fits your requirements (no more, no less) – from full on-site mapping services to rentable equipment. All options can be tailored to your needs and come with the same GxP-grade accuracy and compliance.

How the on-site warehouse mapping service works

The ultimate solution if you need to meet requirements quickly. In this package, our team of validation professionals handles every step of the mapping process for you – planning, installation, and reporting.

  • The project is scoped together with one of our specialists.
  • Our validation team develops the protocol, and you review.
  • Our specialists conduct the mapping study on your site.
  • Your results are analyzed, and you receive the final report.
  • If relevant, we train your team in the process for future studies.

How the remote warehouse mapping service works

The mapping service also comes in a remote version. Our experts still take care of everything from protocol to the final report – your team simply places the data loggers in the warehouse following our guidance.

  • One specialists scope the project toghether with your team.
  • Our validation team develops the protocol, and you review and sign off.
  • You install the loggers according to the protocol and under guidance from our specialists.
  • Our team analyze your mapping data and develops the report.
  • You receive the final report along with any recommendations based on the findings.
Conduct the study yourself (with specialist backup)

How the temperature mapping kit works

Perform your mappings internally using our GxP-compliant mapping kit with professional-grade equipment, specialized validation software, and access to specialist guidance - if you need it.

  • Consult our specialists: Our experts help define the ideal equipment setup for you.
  • Plan the study: Create digital test plans and logger placement.
  • Set up in minutes: Receive the kit, place the equipment, and connect all loggers with a click.
  • Track the mapping: Track the process and act on issues right away with live monitoring.
  • Create a digital report: Analyze data, create mapping-optimized graphs, and generate digital reports with in the software.
  • Return the kit: Once done, return the kit with the included label.
  • Exit calibration is done: We conduct exit calibration, and you can access certificates in the software.

Download a warehouse temperature mapping catalog

From on-site service to rentable mapping kits - see how all the mapping solutions work in the free catalog.

Initializing ...

Why choose Eupry for your warehouse mapping

  • Fastest execution

    ... with efficient processes and digital mapping tools built for GDP.

  • Integrated compliance

    ... move from mapping to monitoring in a few clicks, no new vendors.

  • One engineer, every step

    .. for on-site and remote services, a single specialist manages your project from plan to report.

  • Specialized GDP focus

    ... temperature compliance for GxP is all we do, giving you deep expertise.

Deliverables

What you get

The exact deliverables will, of course, depend on your requirements (everything you need – nothing more, nothing less). But whether on-site, remote, continuous, or kit rental, you always receive the same high-quality, GxP-compliant results.

  • Approved protocol aligned to GDP/USP <1079.4> and your SOPs
  • Calibrated sensors and kits (ISO 17025) with certificates linked to each device
  • Digital test plan with responsibilities, zones, and acceptance criteria
  • On-site or remote execution with validation checks
  • Deviation handling and rationales for any departures
  • Analysis and acceptance decision (variability, excursions, MKT)
  • Final audit-ready report (exportable)
  • Recommendations for permanent monitoring sensor placement, alarm thresholds, etc.
  • Post-study audit support and CAPA guidance if needed

How Eupry’s warehouse mapping solution is different from alternatives

  • No manual Excel or USB loggers – everything is digital, wireless, and validated
  • Faster turnaround – studies finish in days, not weeks, with instant digital reporting
  • One partner for all compliance – mapping, monitoring, and calibration together lower risk and cost

Proven in healthcare logistics

Eupry is trusted by leading logistics companies such as FedEx, WFS, DSV, and many more to validate their global warehouses. They choose Eupry for:

  • Speed of deployment – large-scale studies with minimal disruption
  • Continuous mapping – no more re-mapping worries across global logistics networks
  • Scalable compliance – harmonized SOPs and reports across global sites

Included calibration - and the fastest solution you'll find

Data loggers are always pre-calibrated, and certificates are linked in the mapping software, meaning no need for manual pairings and no idle time waiting for calibrations.

Plus, with Eupry's on-the-wall calibration solution, you can handle all calibrations on-site and in minutes, and thereby, reduce the time you spend on calibration by up to 95%.

Client Testimonials

  • “The plan for the mapping study was designed according to our needs and installed with the help of the Eupry Quality team. Eupry was very professional and informative throughout the process, providing us with high-quality service.”

    Joakim Sund

    Quality Assurance Specialist at DSV Sweden

  • “Eupry’s mapping process was fast, precise, and user-friendly.“

    Andreas Schultz

    Quality Manager at Worldwide Flight Service

  • “Eupry has been an important player, helping us do the mapping of the cool storage but also the ambient storage.“

    Anders Rasmussen

    Senior Logistic Manager at Dechra Pharmaceuticals PLC

  • “It was great working with the Eupry team. There was immediate assistance whenever required.”

    Krishna P. Kurada

    Quality Assurance at Sciegen Pharmaceuticals

The software

IT-validated mapping software

that gives you a complete overview

Data is automatically transferred from the wireless data loggers to the validation software where you can plan and track your study and coduct your analysis and generate reports.

The platform is IT-validated and accessed through a web app.

No downloads needed (= your IT department will love it).

  • Complete overview of your mapping in real-time
  • Digital reporting and audit-ready exports
  • Access to data from anywhere in the world

How does the mapping software work?

  • Start your mapping

    Add facilities, review data logger info, and see calibration certificates.

  • Create test plans

    Document training of your team, define data logger placement, etc.

  • Conduct your study

    Run tests, add commenrs, and register non-conformities.

  • Analyze the findings

    Analyze data, view graphs and box plots, and generate reports.

Case

How DSV conduct GDP warehouse mapping with Eupry

Before DSV Sweden could utilize their new healthcare logistics warehouse, they needed to ensure its ability to maintain temperature conditions in a way that was both swift and GDP compliant.

The sensors

The sensors work as easily-changeable calibration “antennas” that allow you to calibrate without switching devices – making it the most cost-effective calibration solution on the market.

Tip! Can’t find what you are looking for? These are just examples; see all options in the catalog.

The solution offers sensors for all temperature mapping requirements - here are some examples:

P1T - External Temperature Sensor

  • Operating range: -50°C to +50°C (-58°F to 122°F)
  • Resolution: 0.01°C (0.018°F)

P1TH - External Temperature & Humidity Sensor

  • Operating range: 2°C to 50°C (35.6 °F to 122 °F)
  • Resolution: 0.01°C (0.018°F) 0.01 %RH
  • Humidity range: 20-80% RH (Non-condensing)
  • Extended humidity range: 0-99% RH (Non-condensing)

P1CTH - External CO2, Temperature & Humidity Sensor

  • Operating range: 2°C to 50°C (35.6 °F to 122 °F)
  • Resolution: 0.01°C (0.018°F) 0.01 %RH
  • Humidity range: 20-80% RH (Non-condensing)

P2T - External Temperature Probe

  • Operating range: -90 °C to +50 °C (-130 °F to 122 °F).
  • Resolution: 0.03 °C (0.054 °F)

P2TH - External Temperature & Humidity Probe

  • Operating range: 2°C to 50°C (35.6 °F to 122 °F)
  • Resolution: 0.01°C (0.018°F) 0.01 %RH
  • Humidity range: 20-80% RH (Non-condensing)
  • Extended humidity range: 0-99% RH (Non-condensing)

HC2A - High Precision Humidity Probe

  • Accuracy @23 °C: ±0.5 %rh
  • Application range: -50 to 100 °C
  • Sensor element: HYGRIMER HT-1
  • Long-term stability: <1 %rh per year with clean air
Product catalog

See all sensor and data logger options in the product catalog

See how the warehouse mapping solution works and find all product options in our free catalog.

  • Technical specifications
  • All sensor options
  • Solution packages
How it works for

Ambient warehouse storage

For ambient storage areas with temperatures ranging from 15°C to 25°C, we recommend our standard data loggers – usually with sensors calibrated to three points in our ISO 17025-accredited lab.

The number of data loggers needed varies based on your storage size. A small room might require 15 to 30 loggers, while a larger warehouse could need over 300. Our in-house quality department can assist in assessing floor plans and defining the exact number of sensors for your needs.

All data loggers follow a naming convention to make it easier for you to locate specific devices in larger areas.

Why it works:

  • Tailored recommendations based on your facility
  • Custom logger counts based on space
  • Consistent naming for easy identification
How it works for

Cold warehouse storage

Our standard data loggers with ISO 17025 accreditation are also ideal for colder storage areas. The method follows ambient warehouse though the temperature variance might be higher in certain areas of the warehouse causing the need for further data loggers.

The number of data loggers needed varies based on your storage size. Our in-house quality department can assist in assessing floor plans and defining the exact number of sensors for your needs.

All data loggers follow a naming convention to make it easier for you to locate specific devices in larger areas.

Why it works:

  • Tailored recommendations based on your facility
  • Custom logger counts based on space
  • Consistent naming for easy identification
Beyond mapping

One vendor, all you need for temperature compliance

Eupry is more than mapping. We have created one solution for all your temperature compliance: From mapping to monitoring and calibration – all in one GxP-compliant platform, giving you a single source of truth and full control across all sites.

No gaps, no mess.

  • Print audit reports in 3 clicks
  • Track compliance on any screen
  • One vendor, less complexity, lower costs

We have saved around 50-70% of the time we spent on temperature monitoring.

Anders Rasmussen, Senior Logistics Manager, Dechra Pharmaceuticals

FAQ

FAQ: Eupry’s warehouse temperature mapping services

What makes Eupry’s warehouse mapping different?

Engineer-led services with validated loggers, digital software, and ISO-accredited calibration; everything in one package.

How fast can Eupry deliver a warehouse mapping?

Most studies are completed in 7–14 days, with options for remote execution to speed up timelines.

Do I need to re-map my pharmaceutical warehouse every season?

Not with Eupry’s continuous mapping option. Risk-based triggers and always-on verification reduce the need for seasonal re-mappings.

How many sensors will Eupry provide for warehouse mapping?

We supply calibrated sensors based on your warehouse size and risk profile, covering hot/cold spots and representative areas.

Is calibration included in the warehouse mapping service?

Yes. Eupry’s ISO 17025 accredited, on-the-wall calibration is included — no downtime or extra loggers needed.

Can Eupry run warehouse mapping remotely?

Yes. We ship logger kits, guide your team step-by-step, and deliver the same audit-ready report as on-site service.

Which standards does Eupry’s warehouse mapping service comply with?

GDP, GMP, USP <1079.4>, CEIV (for logistics), FDA 21 CFR Part 11, and ISO 27001 for data security.

How does Eupry link mapping to monitoring of pharma warehouses?

We hand over results directly into monitoring — placing sensors, setting alarms, and ensuring continuous compliance in the same platform.

Get started with your warehouse temperature mapping solution

Download our temperature mapping catalog to explore product options and technical specifications – or book a session with one of our specialists to get answers, guidance, and a tailored price quote for your project.