Calibration in seconds for the FMS you already have
A non-disruptive upgrade of your facility monitoring. Keep your cabling, PLC, SCADA, and historian. Instruments arrive pre-calibrated and traceable, and the point goes back in service in seconds instead of waiting out a calibration window.
Trusted by 1,100+ GxP companies worldwide
Every 4–20 mA loop is calibrated where it hangs
The point
Equipment
Time
Frequency
The certificate
Calibration becomes a property of the instrument
Every step that forms the measured value happens inside the instrument. The calibration travels with it, which means it can be done before the instrument reaches your site.
Calibrated
ISO/IEC 17025 accredited calibration in our laboratory. Every instrument ships with its as-left certificate.
Exchanged
Service mode, swap, check the reading, back in service. No loop isolation.
Traced
The serial number travels with every measurement, and the certificate is tied to the same number.
Returned
Send the removed instrument back for as-found calibration, as an optional service.
Element | Today | After the upgrade | Change |
Field instrument | Analog 4–20 mA transmitter | Eupry Smart Instrument | New |
Cable | 4-wire run to the cabinet | Same cable, same terminals | None |
Power | 24 V feed in the cabinet | Same feed | None |
PLC rack | Analog input channel | RS-485 communication module | New module |
PLC program | Scaling into tags | Function block into the same tags | New block |
SCADA, HMI, alarms | Screens, trends, alarms | Unchanged | None |
Historian | Existing tags | One new tag per point for the serial number | One tag |
Choose the connection that matches each area
No rewiring needed. Each area can connect through the cable already in the wall, or over Ethernet where you have it.
Existing 4-wire cable
Modbus RTU over RS-485 on the cable already in the wall. Same terminals, same 24 V feed, one communication module per point.
Ethernet
For new builds and areas with OT networking to the field. OPC UA and MQTT Sparkplug B recover buffered data natively.
Existing 2-wire cable
Power and data on one pair for legacy loop-powered points. Talk to us if this is what your site has.
Which PLC platforms are supported
Siemens S7-1500 is the reference design, using the CM PtP RS422/485 module and the Modbus master function block from the TIA Portal library, which carries no licence cost. S7-1200 is validated on the bench.
Rockwell ControlLogix and CompactLogix, ABB AC500, and Emerson DeltaV follow the same pattern, and we confirm the interface module and library for your platform during scoping.
Calibrate the instrument, and the chain is calibrated
A Eupry Smart Instrument sends a finished value in engineering units, protected by a CRC-16 checksum. Your PLC, SCADA, and historian only carry and store it, so the calibration boundary sits at the instrument.
That holds as long as the PLC applies no re-scaling and the firmware stays under Eupry change control. Both are verified during OQ.
Validate once, not every instrument
Qualify the installation once, under your change control. After that, each like-for-like instrument exchange runs under a pre-approved SOP, with no further change control.
The validation package we supply
URS template
Risk assessment template
IQ and OQ protocols
Swap SOP and service mode SOP
Traceability matrix
Supplier audit pack (ISO/IEC 17025, QMS, firmware change control
Element | Likely GAMP 5 category | Owner |
Eupry Smart Instrument, embedded firmware | Category 3 | Eupry validates, you verify at IQ |
PLC communication module and function block | Category 4, or 5 with custom code | You or your system integrator, with our library and test scripts |
SCADA and historian changes | Existing system change | You |
CMMS certificate interface | Interface | You, with our test scripts |
Download the product catalog
Get instant access to all the details and see how it works our catalog.
Start with one panel
Scoping
Point list, cable types, PLC platforms, and the target protocol per area, agreed with your OT and QA teams. We build the business case from your point count, your calibration intervals, your hours per point, and the cost of a production window. We do not quote a saving without your numbers.
Bench validation
End-to-end link on a lab PLC with the chosen module and function block.
Pilot point
One production panel, running next to an existing 4–20 mA point.
Qualification
IQ and OQ using the validation package.
Roll-out
Area by area, with exchanges running under the routine SOP.